File information: | |
File name: | 2220_2230_QuickStartGuideSBG.pdf [preview 2220 2230 QuickStartGuideSBG] |
Size: | 709 kB |
Extension: | |
Mfg: | Keithley |
Model: | 2220 2230 QuickStartGuideSBG 🔎 |
Original: | 2220 2230 QuickStartGuideSBG 🔎 |
Descr: | Keithley 2220 2220_2230_QuickStartGuideSBG.pdf |
Group: | Electronics > Other |
Uploaded: | 22-03-2020 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name 2220_2230_QuickStartGuideSBG.pdf Series 2200 Multi-Channel Power Supplies Quick Start Front Panel and Programming Operation Guide Introduction This operating guide describes front panel operation and corresponding SCPI command code to perform essential functions of the model 2230-30-1 Triple Channel Power Supply and the model 2220-30-1 Dual Channel Power Supply. References to the third channel specifically apply to the model 2230-30-1 triple channel power supply. Single Channel Operation The series 2200 multi-channel power supplies have all channels enabled in their default state. However, any channel can be disabled and enabled independently. The following example demonstrates the steps to enable and output a voltage on channel 2. Front Panel Operation STEP 1 Enabling Channel 2 1. Press Menu. 2. Use the arrow keys or the navigation wheel to select Enable Channels. 3. Press Enter to enter the submenu. 4. Use the arrow keys or the navigation wheel to select Enable/Disable CH2. 5. Press Enter to enter the submenu. 6. Use the arrow keys or the navigation wheel to select Enable CH2 (default). 7. Press Enter to enable channel 2. 8. Press Esc a couple of times to return to the main display. STEP 2 Setting the Output Voltage on Channel 2 9. Press CH2. 10. Press V-Set. 11. Use the arrow keys, numeric keypad, or the navigation wheel to enter the desired voltage output value. If using the arrow keys or the navigation wheel, use the left arrow key to highlight the digit that represents the resolution for adjustments. 12. Press Enter to set the voltage. STEP 3 Setting the Current Limit on Channel 2 13. Press I-Set. 14. Use the arrow keys, numeric keypad, or the navigation wheel to enter the current limit. If using the arrow keys or the navigation wheel, use the left arrow key to highlight the digit that represents the resolution for adjustments. 15. Press Enter to set the current. 1 STEP 4 Turning on the Output 16. Press Output On/Off to turn on the output. Remote Operation The following SCPI command example enables channel 2, sets the voltage output to |
Date | User | Rating | Comment |